Intel P4000CP Server System Firmware 01.08.0003

Versions: - BIOS: 01.08.0003 - ME: 02.01.07.112 - BMC: 1.17.4151 - FRUSDR: 1.08 BIOS Changes: - Added C0 microcode version 0x405 for Intel Xeon processor E5-2600/2400 v2. - Quiet Boot option doesn't work sometimes. - BIOS can't automatically detect the boot files on the local HDD in EFI optimized boot mode. - Utility such as DMIDECODE and SYSCFG utility can't get SMBIOS information under UEFI RHEL 6.2. - Device on PCIe slot 4 cannot be recognized on Intel Server Board S2400SC. - NIC1 Port2 PXE still shows as a boot option even when disabled in setup on on Intel Server Board S1400SP. - Some add-on graphics card have compatibility issues with Microsoft Windows 7. - The length of BMC user password doesn't meet the specification. - S3 resume will hang sometimes. - NM Power reading is incorrect on Intel Server Boards S2400SC and S2400EP. - Issue on Intel Workstation Board W2600CR2 w/ Nvidia Quadro K5000 video adapter. - Update USB Stack to fix several USB issues. - HDD Driver Fault LED can't be set on Intel Server Board S2400LP. - Update BIOS to higher UEFI version causes some failures with the flash utility. - System will hang after setting NIC1 Port1 to Disabled and then performing a reboot on Intel Server Board S4600LH. - Correct SMBIOS Type 8 E-USB Connector Port Type on Intel Server Board S4600LH. - Add Fast Video feature on multiple platforms. - Update Onboard LAN Oprom incl. 1G/10G PXE, 10G FCoE, iSCSI. - Update ACM version. - Add support for the Intel Xeon processor E5-2600 v2 series - bootable only. - Add a warning message for the first boot if an Intel Xeon processor E5-2600 v2 production processor is inserted. - Add NTB support for Intel Server Board S2600CO. - Serial Over Lan function works if Console Redirection is either disabled or enabled. - Update ME version. - Does not display add-in card option rom in Quite Boot Mode. - Update help strings for setup item "Memory SPD Override". - Add Intel Server Board S4600LH support for production. - Update Board Pre-link Initial Values, VGA selection routine to cover up to four sockets on Intel Server Board S4600LH. ME Changes: - ME may fail to perform reset initiated with IPMI command (02h Cold Reset or DFh Force ME Recovery) - observed after few hundreds of successful resets. - CPU Memory Throttling Status Sensor gets latched in "upper non recoverable" state following Memory Throttling event after G3. BMC Changes: - S4600LH: Updated to FRUSDR 19 package - S2600JF: Updated to FRUSDR 1.10 package - S2400SC: Updated to FRUSDR 1.08 package - S2400EP: Updated to FRUSDR 1.01 package - S1400FP: Updated to FRUSDR 1.01 package - S2600WP: Updated to FRUSDR 1.07 package - S2400BB: Updated to FRUSDR 1.02 package - S1600JP: Updated to FRUSDR 1.00 package - Fixed typo in uboot code for S1400FP - VFP power led always solid green while system into S1 state. - FW versions retrieved by IHC are incorrect. - PSU Config Error dessert event not in SEL after removal of incorrect power supply. - Fix a DIMM Thrm Mgn error in SEL while load BIOS EPSD default - Embedded Web Server SEL logs, added "OS Event" as the sensor name for events generated by 0x0041, to resolve incorrect sensor name & type of SEL after Windows 2008 R2 64bit graceful shutdown - Remove the option of selecting IPv6 address from LCP. - Some special characters show incorrectly on the LCP - The last BIOS POST code on the LCD panel doesn't match with the boards POST CODE LED. - Failed to test PEF Bit for Get PEF Capabilities. - LCP displays "No BIOS POST C" when enter into LPC under VIEW menu. - Connecting LCP to faulty system (system which keeps logging events) then LCP is unusable. - Multiple KVM socket error and media redirection errors - Embedded Web Server - JViewer "Error opening video socket" (Console Redirection Fails) - Web Console Remote Session check. - BMC FW versions displayed by LCP are incorrect - SOL session started in SMASH session times out after 5 minutes - SSH SMASH session does not allow settings1/timeout value greater than 600 seconds. - LCP Configuration LAN Subnet Mask shortened name incorrect. - VBAT voltage is low from BMC sensor reporting. - PEF Postpone timer test failing - S4600LH: LCP displays incorrect Server Name - LCP: Active event is displayed incorrectly - LCP custom string not replacing the banner - Embedded Web console not displaying sensor values for sensors from another controller - IPv6 is not supported on LCP, but the "Conf" screen showed an option to configure IPv6 address. - Update PSSF162202A firmware - Bootloader changes - CRC 16 changes to fix firmware update failure issue. - Fix for READ_EIN and READ_PIN calculation - Fix includes Embedded Web Server reporting 0 W, double Power value workaround for ME issue. - Add auto detection, sensor, and Fan Speed Control support for Intel Xeon Phi Coprocessor adapters - Added additional product ID for Intel Xeon Phi Coprocessor - S4600LH: Change maximum link speed of RMM4 Dedicated NIC to 100Mbps - Fix wrong slot number mapping for S2600GZ/S2600GL. Slot numbers were reversed. - 1200 W 02 F PSU FW file name was specified in hex instead of decimal. - Correcting the same to maintain consistency and for correct release notes generation. - S4600LH: LAN sku, doesn't have Power button. - BMC shouldn't support "stayoff" option in power restore policy. - Restore policy should be POWERON by default. - S2600JF and S2600WP: IO Mod Presence shows not present when SAS Module is present. - Power Unit Redundancy sensor did not behave as expected. - The Power Unit Redundancy sensor was not getting rearmed when AC/DC Input power was removed and then restored. - When interrupting input power from one of the redundant power supplies, the Status LED will blink green. - Restoring power to the power supply causes the Status LED to return to solid green and there is a SEL entry for Redundancy regained. - Scale CFM sensor reading by B value in SDR. - Platforms are using different scaling factors in the SDR for the system CFM sensor. This change reads the scaling factor from the SDR and adjusts the raw sensor reading accordingly. - When a Power Supply was inserted, the PS Redundancy sensor was not getting rearmed. - The PS Redundancy sensor is rearmed when a PS is inserted and full redundancy is regained. - When redundancy is regained, the LED should stop blinking and turn solid green. - There should also be a Redundancy Regained SEL event logged. - Added: Disable POST codes LED output after system has completed POST FRUSDR Changes: - S2600CP.sdr: Modify sensor number 02 "Pwr Unit Redund" Remove De-assertion event from FF00 change to 0000. - S2600CP.sdr: Modify sensor number 70/71 "P1 Status"/"P2 Status" Assertion Event Mask/Deassertion Event Mask/Reading Mask to 8200. - S2600CP.sdr: Modify sensor number 90/91 P1 VRD Hot/P2 VRD Hot Sensor Capabilities to 40. - S2600CP.sdr: Modify sensor number 94~97 P1 MEM01 VRD Hot/P1 MEM23 VRD Hot/P2 MEM01 VRD Hot/P2 MEM23 VRD Hot Sensor Capabilities to 40. - S2600CP.sdr: Modify sensor number F0~FE,60~68 HDD 0 Status to HDD 23 Status Assertion Event Mask/Deassertion Event Mask/Reading Mask to 8300. - S2600CP.sdr: Modify sensor number 34/35 'P1 MTT"/"P2 MTT" M = 0x05, B=0x00, Rexp/Bexp = 0xF0. - Update FRUSDR utility Version 11.0 Build 14.

  • Разработчик: Intel
  • ОС: Windows All
  • Размер: 37.1 MB
Скачать